suche 36x36
  • Admin-Scout-small-Banner
           

    CURSOR Admin-Scout

    get the ultimate tool for Informix

    pfeil  
Latest versionsfixlist
14.10.xC10 FixList
12.10.xC16.X5 FixList
11.70.xC9.XB FixList
11.50.xC9.X2 FixList
11.10.xC3.W5 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

Informix - Problem description

Problem IT32614 Status: Closed

THE AUS_WORK_LOCK TABLE REMAINS ALONG WITH TK_ATTRIBUTES OF 924 WHEN AUS
EVALUATOR STARTS WHEN AUS REFRESH IS STILL RUNNING

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
The AUS evaluator and AUS refresh are scheduled (by default) to
run around 1am.   The days of the week can be configured.

If the system is very big, then the refresh might run for over
24 hours and when this occurs, the next evaluator run will start
and immediately stop but the aus_work_lock table is not dropped,
the tk_attributes is still set to 924 (and not 412) and the
tk_next_execution value might also not be correct depending on
how the AUS evaluator has been configured.   This means that the
AUS evaluator will no longer run, which also means that there is
no refresh of statistics and this could lead to query
performance problems.

The problem can be resolved by manually dropping the
aus_work_lock table and updating tk_attributes to 412 (and if
needed, altering tk_next_execution to a future datetime value)
for the AUS evaluator record.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC5.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 (when available) or    *
* 14.10.xC5.                                                   *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC5.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 (when available) or    *
* 14.10.xC5.                                                   *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC15 and 14.10.xC5.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
21.04.2020
29.12.2020
29.12.2020
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download