Informix - Problem description

Problem IT33697 Status: Closed

DIRECT REMOTE SELECT TO PRI FROM LOCAL HDR / RSS WITH 4 CONNECTION
MANAGERS AND SLA GROUPS MAY RESULT IN 908 / 27001

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
This reproduces with IBM Informix 12.10.FC14 and IBM Informix
CSDK 4.50.FC3
This does NOT reproduce with IBM Informix 14.10.FC3 and IBM
Informix CSDK 4.50.FC3
This reproduces with 4 Connection Managers
This does NOT reproduce with 3 Connection Managers
This reproduces when Connection Manager SLAs are placed in a "CM
SLA Group" group
This does NOT reproduce when no Connection Manager SLAs are
placed in a "CM SLA Group" group

With 3 Connection Managers running and jj1210fc14a_tcp (running
on jj-1410fc3-a) the current HDR Secondary and jj1210fc14b_tcp
(running on jj-1410fc3-b) the current HDR Primary:
==========
[informix@jj-1410fc3-a ~]$ export INFORMIXSERVER=jj1210fc14a_tcp
[informix@jj-1410fc3-a ~]$ echo "select * from
sysmaster@jj1210fc14b_tcp:sysha_type" | dbaccess sysmaster

Database selected.

ha_type       1
ha_primary    jj1210fc14b_tcp
ha_secondary

1 row(s) retrieved.
==========
Starting a 4th Connection Manager and the following results
after a 60 second timeout (i.e. presuming LISTEN_TIMEOUT
reached):
==========
[informix@jj-1410fc3-a ~]$ echo "select * from
sysmaster@jj1210fc14b_tcp:sysha_type" | dbaccess sysmaster

Database selected.


  908: Attempt to connect to database server (jj1210fc14b_tcp,
conerr=-27001, oserr=0) failed.
Error in line 1
Near character position 51
==========
The following may be reported in the PRIMARY online.log
==========
13:07:48  (2) soctcp_sighand failed: ASF error: -25579, errno: 0
==========
Shutting down  any single Connection Manager and it works
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix 12.10.xC14 and earlier versions.           *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* DIRECT REMOTE SELECT TO PRI FROM LOCAL HDR / RSS WITH 4      *
* CONNECTION MANAGERS AND SLA GROUPS MAY RESULT IN 908 / 27001 *
****************************************************************
* RECOMMENDATION:                                              *
****************************************************************
Local Fix:
Upgrade to 14.10
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix 12.10.xC14 and earlier versions.           *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* DIRECT REMOTE SELECT TO PRI FROM LOCAL HDR / RSS WITH 4      *
* CONNECTION MANAGERS AND SLA GROUPS MAY RESULT IN 908 / 27001 *
****************************************************************
* RECOMMENDATION:                                              *
****************************************************************
Comment
Upgrade to Informix 12.10.xC15 or later.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
27.07.2020
29.12.2020
29.12.2020
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download