suche 36x36
  • Admin-Scout-small-Banner
           

    CURSOR Admin-Scout

    das ultimative Tool für Informix

    pfeil  

Informix Machine Notes

Hier finden Sie aktuelle Machine-Notes zu Informix-Produkten, die wir für Sie herausgesucht haben.




                      =================================
                            MACHINE SPECIFIC NOTES
                                    FOR
                IBM Informix Database Server 12.10.TC4 PRODUCT RELEASE
                                 ON Windows 
                               DATE: 03 Jun 2014
                      =================================

OS Information : Built on Windows Server 2003, Certified on Windows XP 
                 (except Home Edition), Windows Server 2008,
                 Windows Vista (except Home Edition),
                 Windows 7 (except Home Edition),
                 Windows 8 (except RT Edtion), 
                 Windows Server 2012 and 2012 R2.

System Requirements
===================

1.  This product is built on Windows Server 2003 with Service Pack 2 using the
    following compiler from Microsoft Visual Studio 2008 (Version 9.0.21022.8):

        Microsoft Visual C++ 2008 91605-270-200004-60370

2.  Operating system patches information for the IBM Informix Database Server

    The following patches are required if you intend to configure Informix 
    Database Server instances with larger than the default shared memory size, 
    such as increasing the number of buffers and locks from their default size 
    during installation.

    Windows 2003 Service Pack 2

        948656 Fix for "A program that allocates a large block of contiguous 
               memory may not start or may intermittently fail in Windows 
               Server 2003 with Service Pack 2."

    Windows XP Service Pack 2

        894472 Fix for "Third-party programs that require lots of memory do 
               not run in Windows XP Service Pack 2."

    For information about Microsoft service packs and patches, see the Microsoft
    Support web site at http://support.microsoft.com.

3.  Enable Connections on Windows Vista

    To enable connections between database servers on the Vista operating
    system, you must enable network discovery and NetBIOS over TCP/IP.

    To enable connections:

    1) From the Control Panel, double-click Network and Sharing.
    2) In the Sharing and Discovery section of the Network and Sharing Center,
       click Network discovery and then Turn on network discovery.
    3) In the Network section, click View Status next to the Local Area
       Connection.
    4) In the Local Area Connection Status dialog box, click Properties.
    5) In the Local Area Connection Properties dialog box, choose the
       appropriate Internet Protocol Version and click Properties.
    6) In the Internet Protocol Version Properties dialog box, click Advanced.
    7) On the WINS page of the Advanced TCP/IP Settings dialog box, click
       Enable NetBIOS over TCP/IP and then click OK.
    8) Continue clicking OK or Close until all dialog boxes are closed.

4.  IBM Informix Database Server uses the libraries and utilities provided by
    the IBM Global Security Kit (GSKit) for data encryption and Secure Sockets
    Layer (SSL) communication. The GSKit is bundled with the server and will
    be installed on your machine as part of the server installation process.
    Here are more details on the GSKit:

       a. The GSKit is also bundled with other IBM products and might
          already be present on your machine. If the GSKit was previously
          installed, but is older than version 8.0.50.20, Informix server will 
          upgrade the GSKit on your machine to version 8.0.50.20. If GSKit is 
          not installed, Informix server will install GSKit in 
          \Program Files\ibm\gsk8 directory on your machine.

       b. The GSKit installation directory must have 25 MB of free disk space.

5.  Using BladeManager 4.20

    If the GUI BladeManager wblademgr.exe is used, Microsoft .NET Framework v2 
    or higher is required to be installed on the system.

6.  Installation Prerequisite on Windows 7 or Later Versions

    For Windows 7 and subsequent Windows versions, you must turn off User 
    Account Control (UAC) security before you install IBM Informix®.

    For information about how to create groups, add users to groups, and 
    turn off User Account Control, see your Windows documentation.

Check the following web site for the latest Windows system requirements
for IBM Informix Database Server:

    http://www-01.ibm.com/support/docview.wss?rs=630&uid=swg27013343


System Configuration
====================
 
1.  Location of Shared Memory
 
    The ONCONFIG variable SHMBASE is recommended to be set to the following:
 
        SHMBASE 0xc000000L

2.  Support maximum shared memory

    The database server can access shared-memory larger than two gigabytes 
    on Windows. However, you must enable this feature with an entry in the 
    Windows boot file.

    To add the entry, edit the boot.ini file (located in the top level, or 
    root directory). You can either add a new boot option or use the currently 
    existing boot option. To enable support for more than two gigabytes, add 
    the following text to the end of the boot line: 

        /3GB 

3.  Administrator permission for running server utilities

    On Windows Vista, Windows 2008 and Windows 7, you must run any 
    server utility commands with administrator permission: for example, 
    the 'oninit -iy' command to initialize the server.

    To run Informix utility commands as an administrator, from the Start menu, 
    choose the Informix server name and then choose "Run as administrator". 
    A command prompt with administrator permissions opens.


Feature Notes  (alphabetized by feature)
=============

1.  Informix Interface for TSM

    The Informix Interface DLL for TSM is installed as 
    
        %INFORMIXDIR%\bin\libtxbsa.dll  

    This interface is built with TSM API version 5.1.6.

    To use Tivoli Storage Manager with Informix databases, refer to IBM 
    Informix Backup and Restore Guide.

2.  IPv6 Support 

    The Informix database server supports Internet Protocol Version 6 (128 Bit 
    Internet Addresses) as well as IPv4 (32 Bit Addresses).

    In order for the machine name that is specified in the SQLHOSTS registry 
    to resolve to the correct IP address, the name services files on the 
    Operating System should be correctly configured.

    For compatibility with earlier version of Informix client and server 
    products, assign each host name with both an IPv4 address and an IPv6 
    address. If the listener needs to be bound to an IPv4 address, and the 
    name services resolve the name in the order of the IPv6 address followed 
    by the IPv4 address, then an explicit IPv4 address needs to be put in the 
    nodename field of server registry. 

3.  J/Foundation (Java in the Server)
 
    J/Foundation supports the JRE 6.0 release from IBM Corporation.

    The JRE 6.0 is available under %INFORMIXDIR%\extend\krakatoa\jre and
    should be used with J/Foundation.

    To use this JRE, set the value of the ONCONFIG variable JVPJAVAHOME as
    follows:

        JVPJAVAHOME    <jvphome>/jre
            where <jvphome> is %INFORMIXDIR%\extend\krakatoa

    For IBM Informix Database Server ONCONFIG settings for J/Foundation,
    refer to "onconfig.std" in %INFORMIXDIR%\etc.

    Java Attach API
    ------------------
    There is a known defect (IZ73533) in the IBM Java SE Runtime Environment SR7
    where if the Attach API is enabled, it causes high CPU utilization. In order
    to avoid this behavior, the Attach API has been disabled by setting the
    following server ONCONFIG parameter:

        JVPARGS -Dcom.ibm.tools.attach.enable=no
 
4.  LDAP Authentication 

    This feature is set up and configured like the Pluggable Authentication
    Module (PAM) that is used on UNIX and Linux. Use the LDAP Authentication 
    Support module when you want to use an LDAP server to authenticate your 
    system users.

    The authentication module is a dynamic link library that resides in the 
    %INFORMIXDIR%\dbssodir\lib\security directory. The parameters of the module
    are listed in the %INFORMIXDIR%\dbssodir\pam.conf file. 

    The source code for a fully functional LDAP Authentication Module and 
    samples of the required configuration files are included in the 
    %INFORMIXDIR%\demo\authentication directory. You can modify the code for 
    your specific LDAP Authentication Support module.

5.  Network Protocols

    The following protocol(s)/interface(s) are supported on this platform:
 
      SOCKETS using TCP/IP
      IPC using named pipe

      To use SOCKETS with TCP/IP:

          a. The NETTYPE entry in the ONCONFIG file and the value data of 
             PROTOCOL in the SQLHOSTS registry entry must contain "onsoctcp"

          b. To enable an IBM Data Server Client to connect to the database 
             server, the NETTYPE entry in the ONCONFIG file and the value 
             data of PROTOCOL in the SQLHOSTS registry entry must contain 
             "drsoctcp"

             If a CLI or JCC client wants to connect to the database server 
             through DRDA while supporting SQLI connections, you must add a 
             DBSERVERALIASES entry to the ONCONFIG file that corresponds to
             the SQLHOSTS registry entry.

      To use IPC (interprocess communication) with named pipe:

          a. The NETTYPE entry in the ONCONFIG file and the value data of 
             PROTOCOL in the SQLHOSTS registry entry must contain "onipcnmp".
 
6.  OnLine Backup and Restore (ON-Bar)
 
    ON-Bar uses the XBSA interface. Some of the functions invoked by ON-Bar 
    are in a dynamic link library supplied by third party storage management 
    vendors. For ON-Bar to access these functions, you must specify the library 
    name and location in the BAR_BSALIB_PATH parameter in the ONCONFIG file. 

    For example, if you are using PSM: 

         Set BAR_BSALIB_PATH to %INFORMIXDIR%\bin\libbsapsm.dll

    For example, if you are using TSM:

         Set BAR_BSALIB_PATH to %INFORMIXDIR%\bin\libtxbsa.dll 

7.  Secure Sockets Layer

    IBM Informix Database Server uses the libraries and utilities provided by
    the IBM Global Security Kit (GSKit) for Secure Sockets Layer (SSL)
    communication. 

8.  Simple Password Communications Support Module

    The name of the IBM Informix dynamic link library for Simple Password CSM
    on Windows is libixspw.dll. This dynamic link library is installed in
    %INFORMIXDIR%\bin.


Features not supported
======================

1.  Shared Disk Secondary Servers

2.  Mapped users


Known Defects in this release
=============================

For information about known defects in this release, see: 
Click here for a list


Defects Fixed in this release
=============================

For information about defects fixed in this release, see: 
Click here for a list


(C) Copyright IBM Corp. 2002, 2014


Informix EditionenInformix Editionen
Informix Editionen
DokumentationDokumentation
Dokumentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download