Informix - Problem description

Problem IT31293 Status: Closed

ASSERT FAILURE AND CRASH MAY OCCUR WHEN HANDLING INVALID CHARACTERS IN
MULTI-BYTE LOCALES

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
In database environments that are defined with a multi-byte
character locale, for example zh_hk.utf8, there are numerous
byte sequences that are not valid as they do not represent a
defined character. These invalid characters are normally
prevented from being stored as data in tables. If the database
server should encounter such an invalid character then some
operations may fail to correctly handle such a situation
resulting in an Aseert Failure (AF) and crash. The nature of the
AF may be such that a recursive exception occurs causing the
database server to terminate without creating a valid AF file or
shared memory dump.

An example of a server operation that may lead to this type of
problem is the SQL REPLACE function.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC14 and 14.10.xC4.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Update to Informix Server 12.10.xC14 or 14.10.xC4 (when      *
* available).                                                  *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC14 and 14.10.xC4.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Update to Informix Server 12.10.xC14 or 14.10.xC4 (when      *
* available).                                                  *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC14 and 14.10.xC4.

NOTE: the majority of the fix is included in 12.10.xC14,
although a second smaller addition to the fix was added after
the release cutoff and will be present in the next release of
12.10.  However, 14.10.xC4 contains the complete fix.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
15.12.2019
04.03.2020
04.03.2020
Problem solved at the following versions (IBM BugInfos)
12.10.0,
12.10.xC14,
14.10.xC4
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download