Informix - Problem description

Problem IT37820 Status: Closed

RSS CONNECTION MESSAGES NEED TO BE MORE INFORMATIVE AND INCLUDE FAILURE
ERROR CODES

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
The current behaviour is as follows:

07/02/21 09:36:49  DR: new type = RSS
07/02/21 09:37:50  DR: Trying to connect to server,
primary_server. If the specified server is not in Online mode,
bring it to Online mode.
07/02/21 09:37:50  Data replication type and state information
reset. To start DR, use the 'onmode -d' command and wait for the
pair to be operational, before shutting down the database server

As can been seen, the request to make this an RSS server was
issued and after 61 seconds the message stating trying to
connect was produced; this message should be produced when the
request to make this an RSS server is issued. Currently, the
message is produced after what appears to be INFORMIXCONTIME
default (i.e. 60 seconds).

If the request to make the RSS server FAILS, then there should
be a message stating "unable to connect to the primary, please
confirm primary online AND re-issue the request to make this an
RSS". Currently there is no reporting of error codes for
establishing a potential cause of failure to connect to the
PRIMARY.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC15 and 14.10.xC7.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
29.07.2021
26.08.2021
26.08.2021
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download