Known defect list for Informix server 11.70.xC7
Informix server provides periodic fixes for release 11.70. The information below lists the known customer-reported defects in Version 11.70.xC7. This report combines both Windows- and UNIX-specific defects.
APAR
|
Description
|
IC69419 | FRACTION OF SECOND IN GL_DATETIME %F DID NOT DISPLAY AS EXPECTED |
IC72617 | IFXCOLLECT DOES NOT WORK ON WINDOWS SYSTEMS. |
IC78379 | [WINDOWS] USER INFORMIX AND GROUP INFORMIX-ADMIN EXIST AFTER CUSTOM INSTALL SPECIFYING LOCAL SYSTEM ACCOUNT |
IC81344 | MIXING UP A NON GL_USEGLU SERVER WITH A GL_USEGLU DATABASE SHOULD GIVE A MEANINGFUL ERROR MESSAGE INSTEAD OF -211/-103 |
IC81491 | DBSCHEMA USED REMOTELY BETWEEN 11.70 AND 11.50 DATABASE INSTANCES WILL FAIL WITH ERRORS |
IC81763 | INSTALLER REFUSES TO PUT DEMO SERVER TO NFS MOUNTED STORAGE |
IC81813 | -535 ALREADY IN TRANSACTION WHEN EXECUTING A SPL PROCEDURE THAT CONTAINS A BEGIN WORK STATEMENT FROM A DRDA CLIENT |
IC81894 | ONMONITOR PRODUCES 25582 ERROR ON EXIT |
IC82486 | USING INCORRECT DBONPLOAD SETTING DURING MIGRATION CAN LEAD TO AF AND ABORTED CONVERSION |
IC82507 | ONPLADM MIGHT FAIL WITH GENERIC ERROR MESSAGE IF REQUIRED DBONPLOAD VALUE DIFFERS FROM ITS VALUE DURING ENGINE STARTUP |
IC83706 | CONFUSING NUMBERS IN COLUMN QUEUE IN CDR LIST SERV OUTPUT |
IC83985 | FUNCTIONALITY AND DESCRIPTION OF SYSTEM VALUES IN IFXDEPLOY.CONF FILE IS UNCLEAR |
IC84823 | ONMODE -P -1 JVP STILL CRASHES THE DATABASE SERVER WHEN JVPARGS IS SET |
IC85085 | RUNNING UPDATE STATISTICS ON A TABLE WITH FRAGMENT LEVEL STATS RETURNS AN INCORRECT MESSAGE RELATED TO SBSPACENAME |
IC85171 | SYSADMIN:ALERTCLEANUP FUNCTION MUST BE RECREATED DURING MIGRATION/CONVERSION |
IC85330 | SEQUENTIAL SCAN OCCURS WHEN RUNNING SELECT COUNT(*) ON LARGE TABLE WITH INDEXED COLUMN |
IC85487 | CDR_SERIAL DOES NOT WORK PROPERLY IF YOU ADD A BIG NUMBER BEFORE |
IC85696 | ASSERT WARNING: (PART <= SPTR->NUM_LPARTS) POSSIBLE DURING QUERY EXECUTION |
IC85935 | MESSAGE FAILPOINT: 14100 IN LOAD JOB LOG FILE WHEN LOADING FROM EMPTY FILE AND TABLE CONTAINS LVARCHAR |
IC86079 | ALTER TABLE VIA IFX_GRID_CONNECT RESULTS IN ERROR 19995 WHEN REPLICATE IS NOT HAVING PARTICIPANTS ON ALL GRID NODES |
IC86189 | REMOTE SUB-QUERY HAS INCORRECT QUERY PATH WITH VERY LOW PERFORMANCE |
IC86237 | RPM OPTION OF INSTALLER (IDS_INSTALL) FAILING WITH ARCHITECTURE IS NOT INCLUDED ON LINUX 32BIT |
IC86443 | SELECT WITH WHERE CLAUSE CONTAINING MATCHES CONDITION WITH MULTIPLE WILDCARDS RETURNS WRONG RESULTS WITH CUSTOMIZED LOCALE |
IC86490 | SUPPLIED KRAKATOA HAS OUTDATED TZ INFO |
IC86493 | MISLEADING ERROR MESSAGE, UNEXPECTED RSS AUTHENTICATION FAILURE WHEN HA_ALIAS IS NOT SET |
IC86641 | ASSERTION FAILURES DURING ROLL FORWARD OF RTREE LOG RECORDS AFTER RESTARTING LOGICAL RECOVERY DURING ARCHIVE RESTORE |
IC86642 | WITH PDQPRIORITY SET, THREADS SHOULD NOT BE LEFT IN A AWAIT_MC STATE AFTER STORED PROCEDURE COMPLETION |
IC86671 | DATABASE CANNOT BE DROPPED DUE TO MISSING SYSTEM CATALOG TABLE IF IT WAS UNLOADED ON V11.50 AND LOADED INTO V11.70 |
IC86784 | AN ASSERT FAILURE IN INIT_TERM_PER_VALUE IS POSSIBLE WHEN MULTI INDEX SCAN IS USED |
IC86785 | BTS INDEX CREATION ON SAME TABLE MUCH SLOWER THAN ETX INDEX |
IC86822 | OPTIMIZER PREFERS INDEX PATH OVER SKIP SCAN WHICH RESULTS IN LONGER EXECUTION TIME |
IC86952 | POSSIBILITY OF ERKEY (IFX_ERKEY_2 COLUMN) CORRUPTION |
IC86978 | IWA: CREATING A DATAMART WITH DANISH LOCALE AND DANISH CHARS IN OBJECT RETURNS AQT10205I |
IC86979 | INFORMIX SERVER SENT THE RESULTSET TWICE TO THE ODBC CLIENT IF THE DATABASE IS IN UNICODE |
IC86993 | CDR CHECK REPLICATESET IFX_INTERNAL_SET RETURNS SQL FAILURE 195 WHEN THERE IS NETWORK DELAY BETWEEN SOURCE AND TARGET |
IC86995 | ALTER TABLE ADD ERKEY IS SLOW WHEN TABLE HAS FOREST OF TREES (FOT) INDEX |
IC87059 | EXECUTE PROCEDURE FAILED WITH 211/111 CANNOT READ SYSTEM CATALOG (SYSPROCBODY) AFTER ONUNLOAD/ONLOAD DATABASE |
IC87066 | CDR THREADS NAMES ARE NOT CLEANED UP FROM SYSMASTER:SYSTHREADS TABLES EVEN THOUGH THREADS ARE NO LONGER PRESENT ON THE SERVER. |
IC87067 | SETTING UP A REPLICATE BETWEEN IDS 10.00 AND 11.70 CAN FAIL WITH DIFFERENT SYMPTOMS |
IC87070 | USAGE OF MENU DRIVEN TABLE MODIFICATION CHANGED BETWEEN 11.50 AND 11.70 |