Informix - Problem description
Problem IT29119 | Status: Closed |
RUNNING A SPL THAT INVOLVES THE USE OF ROW TYPE AND MULTISET COLLECTION VARIABLES FAILS WITH ERROR -9875 | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
Running a SPL that uses ROW type and MULTISET collection variables fails with error -9875 if the parameter 'SET' contains 3 values : EXECUTE FUNCTION myfunc('ABCDE', 'ABCDE0001', SET{'FFF'}, SET{123,456,789}) ; 9875: Bad internal structure for collection data: unknown flag value. Error in line 1 Near character position 80 But if same SPL is executed with just two values in 'SET' parameter it runs fine : EXECUTE FUNCTION myfunc('ABCDE', 'ABCDE0001', SET{'FFF'}, SET{123,456}) ; | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of IDS prior to 12.10.xC13. * **************************************************************** * PROBLEM DESCRIPTION: * * Running a SPL that involves the use of ROW type and MULTISET * * collection variables fails with error -9875. * **************************************************************** * RECOMMENDATION: * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 13.05.2019 26.09.2019 26.09.2019 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC13 | |
Problem solved according to the fixlist(s) of the following version(s) |